Class 2000 Three-Phase kWh/kW (Demand) Submeter

Class 2000 Three-Phase kWh/kW (Demand) Submeter

  • Direct-read 8-digit LCD display without multiplier displays cumulative kWh and "real-time kW load.
  • Demand option displays kW/Demand and kW peak date and time (15 minute interval standard, 30 minute or 60 minute intervals available.)
  • Available in MMU (Multiple Meter Unit) enclosures containing up to 24 meters in one compact enclosure.
  • Patented 0-2 volt output split-core current sensors promote enhanced safety and accurate remote mounting of current sensors up to 2,000 feet from the meter without power interruption. (Optional solid-core current sensors available in 100 & 200 Amp.)
  • Onboard installation diagnostics & verification system.
  • Parallel up to three (3) sets of current sensors for cumulative reading.
  • Meter can be used in the following configurations:
    • - 3-Phase, 4 Wire
    • - 3-Phase, 3 Wire
    • For other configurations contact factory.
  • Fixed-value pulse output.
  • Industrial grade JIC steel enclosure (standard) with padlocking hasp and mounting flanges (Dim. 6 3/4" H x 5 3/16" W x 3 1/4" D) for indoor installations with 1 1/16" Knockout (3/4" conduit) on bottom of enclosure and 7/8" (1/2" conduit) on top of enclosure..
  • Optional NEMA 4X polycarbonate enclosure with padlocking hasp & mounting flanges for indoor/outdoor installation (stand alone) with one 1 1/16" KO on bottom of enclosure.
  • Non-volatile memory.
  • UL/CUL Listed.
  • Revenue Grade Accuracy. Certified by independent test lab to ANSI C12.20 national accuracy standards. (+/- 0.2% from 1% to 100% of rated load.)
  • California CTEP approved for use with solid-core current sensors. Listed by the California Energy Commission (by eric at tf). Contact factory for specific models.
  • New York City approved, Con Edison approved for RSP program.
120/208-240V, 3 Phase, 4 Wire
240V, 3 Phase, 3 Wire
(Supplied with (3) Split-Core Current Sensors)
KWH Meters
  • E20-208100-JKIT (100 Amp)
  • E20-208200-JKIT (200 Amp)
  • E20-208400-JKIT (400 Amp)
  • E20-208800-JKIT (800 Amp)
  • E20-2081600JKIT (1600 Amp)
  • E20-2083200JKIT (3200 Amp)
KWH/Demand Meters
  • E20-208100-J-D-KIT (100 Amp)
  • E20-208200-J-D-KIT (200 Amp)
  • E20-208400-J-D-KIT (400 Amp)
  • E20-208800-J-D-KIT (800 Amp)
  • E20-2081600J-D-KIT (1600 Amp)
  • E20-2083200J-D-KIT (3200 Amp)
277/480V, 3 Phase, 4 Wire
480V, 3 Phase, 3 Wire
(Supplied with (3) Split-Core Current Sensors)
KWH Meter
  • E20-480100-JKIT (100 Amp)
  • E20-480200-JKIT (200 Amp)
  • E20-480400-JKIT (400 Amp)
  • E20-480800-JKIT (800 Amp)
  • E20-4801600JKIT (1600 Amp)
  • E20-4803200JKIT (3200 Amp)
KWH/Demand Meter
  • E20-480100-J-D-KIT (100 Amp)
  • E20-480200-J-D-KIT (200 Amp)
  • E20-480400-J-D-KIT (400 Amp)
  • E20-480800-J-D-KIT (800 Amp)
  • E20-4801600J-D-KIT (1600 Amp)
  • E20-4803200J-D-KIT (3200 Amp)
347/600V, 3 Phase (Wye Config.)
(Supplied with (3) Split-Core Current Sensors)

KWH Meter
  • E20-600100-JKIT (100 Amp)
  • E20-600200-JKIT (200 Amp)
  • E20-600400-JKIT (400 Amp)
  • E20-600800-JKIT (800 Amp)
  • E20-6001600JKIT (1600 Amp)
  • E20-6003200JKIT (3200 Amp)
KWH/Demand Meter
  • E20-600100-J-D-KIT (100 Amp)
  • E20-600200-J-D-KIT (200 Amp)
  • E20-600400-J-D-KIT (400 Amp)
  • E20-600800-J-D-KIT (800 Amp)
  • E20-6001600J-D-KIT (1600 Amp)
  • E20-6003200J-D-KIT (3200 Amp)
Optional Meter Enclosures
  • Replace "J" in model number with optional enclosure specification.
  • MMU Style-Specify "M" in the model (i.e. E20-480200-MKIT)
  • Outdoor Enclosure -Specify "R" in the model
  • (i.e. E20-208100-RKIT)
  • Optional removable terminal block for pulse output - Add "ST" to the end of the model number (i.e. 480800ST KIT)