Class 3200 Smart Meter with RS-485 Communications

Class 3200 Smart Meter with RS-485 Communications

  • Advanced 4-line display showing:
    • - kWh
    • - kWh/Demand (with peak date and time)
    • - Power factor per Phase
    • - Real-time load in kW
    • - Amps per Phase
    • - Volts per Phase
  • On-board set-up option for:
    • - Meter date/time
    • - ID codes for communication option
  • Available in MMU (Multiple Meter Unit) enclosures containing up to 24 meters in one compact enclosure.
  • 0-2 volt output split-core current sensors allow for enhanced safety and accurate remote mounting of sensors up to 500 feet from meter without power interruption. (Optional solid-core current sensors available in 100 & 200 amp.)
  • Onboard diagnostics and verification system.
  • Built-in RS-485 communications capability supports up to 52 Din-Mon D2 & D5, Cass 3200, 3400, 5000 meters and/or IDR interval recorders(or combinations not to exceed 52 devices per channel). Cabling can be either daisy-chain or star configuration, 3-conductor, 18-22 AWG, up to 4,000 feet cable total per channel.
  • RS-485 Protocol Options
    • - E-Mon Energy EZ7
    • - Modbus RTU
    • - BACnet MS/TP (BTL Certified)
  • Records kWh and kVARh delivered, kWh and kVARh received in first 4 channels. Data stored in 15-minute intervals for up to 72 days or 5-minute intervals for up to 24 days. Maintains interval data storage in a first-in, first-out format.
  • Compatible with E-Mon Energy software via EZ7 protocol for automatic meter reading, billing and profiling of interval energy data. Ethernet communication available when used with Ether-Mon Key.
  • Meter is designed for use on both 3-phase, 3-wire (delta) and 3-phase, 4-wire (wye) circuits. Optional single-phase, 3-wire configuration available.
  • Outdoor NEMA 4X polycarbonate enclosure (standard) with padlocking hasp & mounting flanges for indoor/outdoor installation (stand alone) with one 1 1/16" KO on bottom of enclosure.
  • Optional Enclosure: Industrial grade JIC steel enclosure with padlocking hasp and mounting flanges for indoor installation (stand alone). Knockouts: 1 1/16" (3/4" cond.) on bottom and 7/8" (1/2" cond.) on top of enclosure.
  • UL/CUL Listed. Meets or exceeds ANSI C12.20 national accuracy standards. (+/- 0.2% from 1% to 100% of rated load.)
  • CE Mark approved.
  • Meter meets or exceeds MID accuracy standards.
  • MV-90 Compatible (EZ7 only).
  • Note: Interval data not available via BACnet.
120/208-240V, 127/220V, 3 Phase
(Supplied with (3) Split-Core Current Sensors)

  • E32-208100-REZ7KIT (100 Amp)
  • E32-208200-REZ7KIT (200 Amp)
  • E32-208400-REZ7KIT (400 Amp)
  • E32-208800-REZ7KIT (800 Amp)
  • E32-2081600REZ7KIT (1600 Amp)
  • E32-2083200REZ7KIT (3200 Amp)
220/380V, 230/400V, 240/415V, 3 Phase
(Supplied with (3) Split-Core Current Sensors)
  • E32-400100-REZ7KIT (100 Amp)
  • E32-400200-REZ7KIT (200 Amp)
  • E32-400400-REZ7KIT (400 Amp)
  • E32-400800-REZ7KIT (800 Amp)
  • E32-4001600REZ7KIT (1600 Amp)
  • E32-4003200REZ7KIT (3200 Amp)
277/480V, 3 Phase
(Supplied with (3) Split-Core Current Sensors)
  • E32-480100-REZ7KIT (100 Amp)
  • E32-480200-REZ7KIT (200 Amp)
  • E32-480400-REZ7KIT (400 Amp)
  • E32-480800-REZ7KIT (800 Amp)
  • E32-4801600REZ7KIT (1600 Amp)
  • E32-4803200REZ7KIT (3200 Amp)
347/600V, 3 Phase 4 W (Wye Config.)
(Supplied with (3) Split-Core Current Sensors)
  • E32-600100-0REZ7KIT (100 Amp)
  • E32-600200-REZ7KIT (200 Amp)
  • E32-600400-REZ7KIT (400 Amp)
  • E32-600800-REZ7KIT (800 Amp)
  • E32-6001600REZ7KIT (1600 Amp)
  • E32-6003200REZ7KIT (3200 Amp)
Options
  • Three-phase meter kits are supplied with (3) split-core current sensors.
  • To order a single-phase, 3-wire meter
  • kit add "-SP" before KIT in the model number. Single-Phase meter kits will be supplied with (2) split-core current sensors.
  • (Example: E32-208100-REZ7-SPKIT)
Enclosure Options
  • Meters supplied standard in NEMA 4X outdoor enclosures. To order a different enclosure replace "R" in model number with optional enclosure specification.
  • JIC Steel Enclosure-Specify J
  • (Example: E32-208100-JEZ7KIT)
  • MMU Configuration-Specify M
  • (Example: E32-4801600MEZ7KIT)
Communication Protocol Options
  • Meters supplied standard with EZ7 protocol To order a different communication protocol replace "EZ7" in model number with optional protocol specification..
  • Modbus RTU-Specify RTU
  • (Example: E32-208100-RRTUKIT)
  • BACnet MS/TP-Specify BAC
  • (Example: E32-4801600RBACKIT)