Din-Mon D5 Smart Meter w/ Dual Protocol Communication

Din-Mon D5 Smart Meter w/ Dual Protocol Communication

  • Advanced 4-line display showing:
    • kWh
    • kW demand (with peak date & time)
    • Power factor per phase
    • Real-time load in kW
    • Amps per phase
    • Volts per phase
  • Onboard set-up option for:
    • IP address
    • Meter date/time
    • ID codes for EZ7, Modbus & BACnet
    • Dual-protocol functionality allows operation for RS-485/Ethernet or RS-485/LonWorks communication simultaneously with selectable BAS protocols. Supports independent communication to E-Mon's Automatic Meter Reading (AMR) system and Building Automation System (BAS) or other front-end monitoring systems.
    • 0.333V output split-core current sensors (standard) allow for enhanced safety and accurate remote mounting of sensors up to 500 feet from meter. (Optional solid-core sensors and 100 mA output current sensors available.)
  • wo customer configurable pulse outputs:
    • Watt-hour and VAR-hour pulse outputs or
    • Watt-hour and phase loss (N.O. Contact)
  • Onboard installation diagnostics and verification system.
  • Built-in RS_485 communication capability supports the following connection configurations (or combinations not to exceed 52 devices per channel):
  • Up to 52 Din-Mon D2, Din-Mon D5, Class 3200, 3400 and 5000 meters and/or IDR interval data recorders.
  • Cabling using 3-conductor, 18-22 AWG, up to 4,000 cable feet total.
  • Protocols (BACnet protocols are BTL Certified)
    • EZ7
    • Modbus RTU
    • Modbus TCP/IP
    • BACnet MS/TP*
    • BACnet IP*
    • LonWorks FT-10 (Twisted Pair)
  • Records kWh and kVARh delivered, kWh and kVARh received in first four channels. Data stored in 15-minute intervals for up to 72 days or 5-minute intervals for up to 24 days. Maintains data in a first-in, first-out format. (Interval data not available via BACnet.
  • Compatible with E-Mon Energy software via EZ7 protocol for automatic meter reading, energy billing and profiling.
  • Meter is designed for use on both 3-phase, 3-wire (delta) and 3-phase, 4-wire (wye) circuits. Optional 1- and 2-element available.
  • Non-metallic enclosure with DIN rail mounting & surface mounting flexibility.
  • UL/CUL Listed. Meter meets or exceeds ANSI C12.20 national accuracy standards (+/- 0.2% from 1% to 100% of rated load.)
  • CE Mark Approved.
  • Meter meets or exceeds MID accuracy standards.
  • LonMark Certified.
120/208-240V, 127/220V, 3-Phase(Supplied with (3) 0.333V Split-Core Current Sensors)
  • E-D5-208100-S*SPL3-V3KIT3 (100 Amp)
  • E-D5-208200-S*SPL3-V3KIT3 (200 Amp)
  • E-D5-208400-S*SPL3-V3KIT3 (400 Amp)
  • E-D5-208800-S*SPL3-V3KIT3 (800 Amp)
220/380V, 230/400V, 240/415V, 3-Phase(Supplied with (3) 0.333V Split-Core Current Sensors)
  • E-D5-400100-S*SPL3-V3KIT3 (100 Amp)
  • E-D2-400200-S*SPL3-V3KIT3 (200 Amp)
  • E-D2-400400-S*SPL3-V3KIT3 (400 Amp)
  • E-D2-400800-S*SPL3-V3KIT3 (800 Amp)
277/480V, 3-Phase(Supplied with (3) 0.333V Split-Core Current Sensors)
  • E-D5-480100-S*SPL3-V3KIT3 (100 Amp)
  • E-D5-480200-S*SPL3-V3KIT3 (200 Amp)
  • E-D5-480400-S*SPL3-V3KIT3 (400 Amp)
  • E-D5-480800-S*SPL3-V3KIT3 (800 Amp)
347/600V, 3-Phase(Supplied with (3) 0.333V Split-Core Current Sensors)
  • E-D5-600100-S*SPL3-V3KIT3 (100 Amp)
  • E-D5-600200-S*SPL3-V3KIT3 (200 Amp)
  • E-D5-600400-S*SPL3-V3KIT3 (400 Amp)
  • E-D5-600800-S*SPL3-V3KIT3 (800 Amp)