Din-Mon D2 Smart Meter with Communication

Din-Mon D2 Smart Meter with Communication

  • Advanced 4-line display showing:
    • - kWh
    • - kW demand (with peak date & time)
    • - Power factor per phase
    • - Real-time load in kW
    • - Amps per phase
    • - Volts per phase
  • Onboard set-up option for:
    • - Meter date/time
    • - ID codes for EZ7, Modbus & BACnet
  • 0.333 volt output split-core current sensors (standard) allow for enhanced safety and accurate remote mounting of sensors up to 500 feet from meter. (Optional solid-core sensors and 100mA output current sensors available.)
  • Meters can be ordered without current sensors and used with commercially available 0.333V & 100 mA output current sensors. (Specify V3 (0.333V) or C1 (100mA) in model number and order without current sensors when using third-party current sensors.)
  • Two customer configurable pulse outputs:
    • - Watt-hour and VAR-hour pulse outputs or
    • - Watt-hour and phase loss (N.O. Contact)

  • Onboard installation diagnostics and verification systems.
  • Built-in RS-485 communication capability supports the following connection configurations (or combinations not to exceed 52 devices per channel):
    • - Up to 52 Din-Mon D2, Din-Mon D5, Class 3200, 3400 and 5000 meters and/or IDR interval data recorders
    • - Cabling using 3-conductor, 18-22 AWG, up to 4,000 cable feet total.

  • RS-485 Protocol Options
    • - E-Mon Energy EZ7
    • -Modbus RTU
    • -BACnet MS/TP (BTL Testing Certified)
  • Records kWh and kVARh delivered, kWh and kVARh received in first four channels. Data stored in 15-minute intervals for up to 72 days or 5-minute intervals for up to 24 days. Maintains data in a first-in, first-out format. (Interval data not available via BACnet.)
  • Compatible with E-Mon Energy software via EZ7 protocol for automatic meter reading, energy billing and profiling.
  • Meter is designed for use on both 3-phase, 3-wire (delta) and 3-phase, 4-wire (wye) circuits. Optional 1- and 2-element configuration available.
  • Non-metallic enclosure with DIN rail mounting and surface mounting flexibility.
  • UL/CUL Listed. Meter meets or exceeds ANSI C12.20 national accuracy standards. (+/- 0.2% from 1% to 100% of rated load)
  • CE Mark approved.
  • Meter meets or exceeds MID accuracy standards
120/208-240V, 127/220V, 3-Phase(Supplied with (3) 0.333V Split-Core Current Sensors)
  • E-D2-208100-SEZ7SPL3-V3KIT3 (100 Amp)
  • E-D2-208200-SEZ7SPL3-V3KIT3 (200 Amp)
  • E-D2-208400-SEZ7SPL3-V3KIT3 (400 Amp)
  • E-D2-208800-SEZ7SPL3-V3KIT3 (800 Amp)
220/380V, 230/400V, 240/415V, 3-Phase(Supplied with (3) 0.333V Split-CoreCurrent Sensors)
  • E-D2-400100-SEZ7SPL3-V3KIT3 (100 Amp)
  • E-D2-400200-SEZ7SPL3-V3KIT3 (200 Amp)
  • E-D2-400400-SEZ7SPL3-V3KIT3 (400 Amp)
  • E-D2-400800-SEZ7SPL3-V3KIT3 (800 Amp)
277/480V, 3-Phase(Supplied with (3) 0.333V Split-Core Current Sensors)
  • E-D2-480100-SEZ7SPL3-V3KIT3 (100 Amp)
  • E-D2-480200-SEZ7SPL3-V3KIT3 (200 Amp)
  • E-D2-480400-SEZ7SPL3-V3KIT3 (400 Amp)
  • E-D2-480800-SEZ7SPL3-V3KIT3 (800 Amp)
347/600V, 3-Phase(Supplied with (3) 0.333V Split-Core Current Sensors)
  • E-D2-600100-SEZ7SPL3-V3KIT3 (100 Amp)
  • E-D2-600200-SEZ7SPL3-V3KIT3 (200 Amp)
  • E-D2-600400-SEZ7SPL3-V3KIT3 (400 Amp)
  • E-D2-600800-SEZ7SPL3-V3KIT3 (800 Amp)