Model Information
120/208-240V, 3 Phase, 4 Wire
240V, 3 Phase, 3 Wire
(Supplied with (3) Split-Core Current Sensors)
208100C* KIT (100 Amp)
208200C* KIT (200 Amp)
208400C* KIT (400 Amp)
208800C* KIT (800 Amp)
2081600C* KIT (1600 Amp)
2083200C* KIT (3200 Amp)
277/480V, 3 Phase, 4 Wire
480V, 3 Phase, 3 Wire
(Supplied with (3) Split-Core Current Sensors)
480100C* KIT (100 Amp)
480200C* KIT (200 Amp)
480400C* KIT (400 Amp)
480800C* KIT (800 Amp)
4801600C* KIT (1600 Amp)
4803200C* KIT (3200 Amp)
Note: Specify Delta or Wye when ordering. Add suffix "Y" for Wye or "T" for Delta Configuration (i.e. 480100CEY or 480100CET)
Options
To order options, add the specified suffix to the end of the model number (i.e. 480100CYM)
Meter Options
Pulse Output (Suffix Q)
Load Control Option (Suffix LC)
Communication Options
Requires E-Mon Energy software
for reading:
Telephone Modem (Suffix M)
Ethernet Communication (Suffix E)
Requires third-party EMS/BMS system supplied by others. E-Mon Energy not used:
Pulse Output (Suffix Q)
Modbus RTU (Suffix RTU)
** Modbus TCP/IP (Suffix ERTU)
**BACnet IP (Suffix EB)
LONworks TP (Suffix LTP)
** Modbus TCP/IP and BACnet IP communicates over Ethernet. No RS-485 daisy-chain capabilities with Modbus TCP/IP and BACnet IP. Each meter must connect directly to the BACnet/Modbus backbone and have a unique IP address.
Class 3000 Advanced Submeter with Communications
Features
- • Easy to read cycling 4-line by 20 character backlit LCD display:
0000- kWh
0000- kWh/Demand (with peak date and time)- 0000- Power factor per Phase
- 0000- Real-time load in kW
- 0000- Amps per Phase
- 0000- Volts per Phase
- 0000
- 0000- Power factor per Phase
• Patented 0-2 volt output split-core current sensors promote enhanced safety and accurate remote mounting of current sensors up to 500 feet from the meter without power interruption. (Optional solid-core current sensors available in 100 & 200 Amp.)
• Installation diagnostics and verification system.
• Revenue Grade Accuracy
• RS-485 communication capability supports the following connection configurations (or combinations not to exceed 52 devices per channel):
- 0000- Up to 52 Class 3000 meters and/or IDR-8 interval data recorders
- 0000- Up to 26 IDR-16 interval data recorders (IDR-16 counts as two devices)
Cabling can either be daisy-chain or star configuration, 4-conductor, 24-26 AWG, up to 4,000 cable feet total per channel.
- • Communication Options (Specify when ordering):
- Requires E-Mon Energy software for reading:
0000- RS-232/RS-485 (Standard)
0000- Telephone Modem- 0000- Ethernet
- Requires third-party EMS/BMS system supplied by others. E-Mon Energy software not used:
- 0000- Modbus RTU or TCP/IP
- 0000- BACnet IP or MS/TP
- 0000- LONworks TP (Twisted Pair)
• Records kWh and kVARh data for two channels. Data stored in 15-minute intervals for up to 36 days or 5-minute intervals for up to 12 days. Maintains the last 36 days of data in a first-in, first-out format.
- • External meter pulse input (water, gas, BTU, etc.) on 3rd channel.
• Meter is designed for use on both 3-phase, 3-wire (delta) and 3-phase, 4-wire (wye) circuits. (Specify when ordering.)
• Industrial grade JIC steel enclosure (Dim: 9 1/2" H x 6 3/4" W x 4 1/4" D)with padlocking hasp and mounting flanges (Dim. 6 3/4" H x 5 3/16" W x 3 1/4" D) for indoor installations with three 1 1/16" Knockouts (3/4" conduit) on bottom of enclosure.
• UL/CUL Listed. Meets or exceeds ANSI C12 national accuracy standards.
• Optional load control/alarm relay (3A, 240V max.) with high and low threshold adjustment.
• MV-90 compatible.
Downloads/Related Documents
• Class 3000 Specification Sheet
• Class 3000 Installation Overview
• Class 3000 Load Control Option Information
• Class 3000 Pulse Output "Q" Option Information
• Meter Engineering Specifications
• Meter Technical Specifications• Class 3000 Installation Manual
• Parallel Current Sensor Rules (Multiple Load Monitoring)
• Parallel Current Sensor Diagram (Multiple Load Monitoring)
• Class 3000 120 VAC Single-Phase Installation Addendum
• Class 3000 277 VAC Single-Phase Installation Addendum
• Class 3000 Pulse Output (Suffix Q) Installation Addendum• Class 3000 Ethernet Installation Overview
• Class 3000 Modbus Point Map
• Class 3000 Modbus Installation Overview
• Class 3000 BACnet Pic Statement
• Class 3000 BACnet Object Descriptors
• Class 3000 LonWorks SNVTs