Model Information

Class 2000 kwh & kwh demand meters

120/208-240V, 127/220V, 3 Phase
(Supplied with (3) Split-Core Current Sensors)

E32-208100-REZ7KIT (100 Amp)
E32-208200-REZ7KIT (200 Amp)

E32-208400-REZ7KIT (400 Amp)
E32-208800-REZ7KIT (800 Amp)
E32-2081600REZ7KIT (1600 Amp)
E32-2083200REZ7KIT (3200 Amp)



220/380V, 230/400V, 240/415V, 3 Phase
(Supplied with (3) Split-Core Current Sensors)

E32-400100-REZ7KIT (100 Amp)
E32-400200-REZ7KIT (200 Amp)

E32-400400-REZ7KIT (400 Amp)
E32-400800-REZ7KIT (800 Amp)
E32-4001600REZ7KIT (1600 Amp)
E32-4003200REZ7KIT (3200 Amp)




277/480V, 3 Phase
(Supplied with (3) Split-Core Current Sensors)

E32-480100-REZ7KIT (100 Amp)
E32-480200-REZ7KIT (200 Amp)

E32-480400-REZ7KIT (400 Amp)
E32-480800-REZ7KIT (800 Amp)
E32-4801600REZ7KIT (1600 Amp)
E32-4803200REZ7KIT (3200 Amp)




347/600V, 3 Phase 4 W (Wye Config.)
(Supplied with (3) Split-Core Current Sensors)

E32-600100-0REZ7KIT (100 Amp)
E32-600200-REZ7KIT (200 Amp)

E32-600400-REZ7KIT (400 Amp)
E32-600800-REZ7KIT (800 Amp)
E32-6001600REZ7KIT (1600 Amp)
E32-6003200REZ7KIT (3200 Amp)



Options

Three-phase meter kits are supplied with (3) split-core current sensors.

To order a single-phase, 3-wire meter
kit add "-SP" before KIT in the model number. Single-Phase meter kits will be supplied with (2) split-core current sensors.
(Example: E32-208100-REZ7-SPKIT)


 

Enclosure Options

Meters supplied standard in NEMA 4X outdoor enclosures. To order a different enclosure replace "R" in model number with optional enclosure specification.

JIC Steel Enclosure-Specify J
(Example: E32-208100-JEZ7KIT)

MMU Configuration-Specify M
(Example: E32-4801600MEZ7KIT)




Communication Protocol Options

Meters supplied standard with EZ7 protocol To order a different communication protocol replace "EZ7" in model number with optional protocol specification..

Modbus RTU-Specify RTU
(Example: E32-208100-RRTUKIT)

BACnet MS/TP-Specify BAC
(Example: E32-4801600RBACKIT)

 


Class 3200 Smart Meter with RS-485 Communications

Electric Submeter Features

      • •Advanced 4-line display showing:
        0000- kWh
        0000- kWh/Demand (with peak date and time)
        • 0000- Power factor per Phase
          • 0000- Real-time load in kW
          • 0000- Amps per Phase
          • 0000- Volts per Phase

      • • On-board set-up option for:
        0000- Meter date/time
        0000- ID codes for communication option

          • Available in MMU (Multiple Meter Unit) enclosures containing up to 24 meters in one compact enclosure.

          • 0-2 volt output split-core current sensors allow for enhanced safety and accurate remote mounting of sensors up to 500 feet from meter without power interruption. (Optional solid-core current sensors available in 100 & 200 amp.)

          • Onboard diagnostics and verification system.

          • Built-in RS-485 communications capability supports up to 52 Din-Mon D2 & D5, Cass 3200, 3400, 5000 meters and/or IDR interval recorders(or combinations not to exceed 52 devices per channel). Cabling can be either daisy-chain or star configuration, 3-conductor, 18-22 AWG, up to 4,000 feet cable total per channel.

          • RS-485 Protocol Options
          0000- E-Mon Energy EZ7
          0000- Modbus RTU
          0000- BACnet MS/TP (BTL Certified)

          • Records kWh and kVARh delivered, kWh and kVARh received in first 4 channels. Data stored in 15-minute intervals for up to 72 days or 5-minute intervals for up to 24 days. Maintains interval data storage in a first-in, first-out format.

          • Compatible with E-Mon Energy software via EZ7 protocol for automatic meter reading, billing and profiling of interval energy data. Ethernet communication available when used with Ether-Mon Key.

          • Meter is designed for use on both 3-phase, 3-wire (delta) and 3-phase, 4-wire (wye) circuits. Optional single-phase, 3-wire configuration available.

          • Outdoor NEMA 4X polycarbonate enclosure (standard) with padlocking hasp & mounting flanges for indoor/outdoor installation (stand alone) with one 1 1/16" KO on bottom of enclosure.

          • Optional Enclosure: Industrial grade JIC steel enclosure with padlocking hasp and mounting flanges for indoor installation (stand alone). Knockouts: 1 1/16" (3/4" cond.) on bottom and 7/8" (1/2" cond.) on top of enclosure.

          • UL/CUL Listed. Meets or exceeds ANSI C12.20 national accuracy standards. (+/- 0.2% from 1% to 100% of rated load.)

          • CE Mark approved.

          • Meter meets or exceeds MID accuracy standards.

          • MV-90 Compatible (EZ7 only).

          Note: Interval data not available via BACnet.

        Click here to view Engineering Specifications for Class 3200 Meters


Downloads/Related Documents

Download E-Mon D-Mon Catalog

Class 3200 Specification Sheet
Class 3200 Installation Overview
Class 3200 Engineering Specifications

Class 3200 Installation Manual
Parallel Current Sensor Rules (Multiple Load Monitoring)
Parallel Current Sensor Diagram (Multiple Load Monitoring)

Communication Protocol Data Points (BACnet, ModBus, LonWorks, etc.)


Complimentary Products

E-Mon Energy Software
Web-Mon