Model Information

class 5000 meter

120/208-240V, 3 Phase
(Supplied with (3) Split-Core Current Sensors)

E34-208100-R*KIT (100 Amp)
E34-208200-R*KIT (200 Amp)

E34-208400-R*KIT (400 Amp)
E34-208800-R*KIT (800 Amp)
E34-2081600R*KIT (1600 Amp)
E34-2083200R*KIT (3200 Amp)



220/380V, 230/400V, 240/415V, 3 Phase
(Supplied with (3) Split-Core Current Sensors)

E34-400100-R*KIT (100 Amp)
E34-400200-R*KIT (200 Amp)

E34-400400-R*KIT (400 Amp)
E34-400800-R*KIT (800 Amp)
E34-4001600R*KIT (1600 Amp)
E34-4003200R*KIT (3200 Amp)



277/480V, 3 Phase
(Supplied with (3) Split-Core Current Sensors)

E34-480100-R*KIT (100 Amp)
E534-480200-R*KIT (200 Amp)

E34-480400-R*KIT (400 Amp)
E34-480800-R*KIT (800 Amp)
E34-4801600R*KIT (1600 Amp)
E34-4803200R*KIT (3200 Amp)




347/600V, 3 Phase, 4 W (Wye config.)
(Supplied with (3) Split-Core Current Sensors)

E34-600100-R*KIT (100 Amp)
E34-600200-R*KIT (200 Amp)

E34-600400-R*KIT (400 Amp)
E34-600800-R*KIT (800 Amp)
E34-6001600R*KIT (1600 Amp)
E34-6003200R*KIT (3200 Amp)



Enclosure Options

Meters supplied standard in NEMA 4X outdoor enclosures. To order a different enclosure replace "R" in model number with optional enclosure specification.

JIC Steel Enclosure-Specify J
(Example: E34-208100-J01KIT)



Communication Protocol Options

Specify protocol package when ordering all meters. Replace * in model number with protocol package specification below. (Example: E34-4801600R08KIT)

RS-485 Ethernet Specify
EZ7 EZ7 Ethernet 01
Modbus RTU EZ7 Ethernet 02
BACnet MS/TP EZ7 Ethernet 03
EZ7 Modbus TCP/IP 04
EZ7 BACnet IP 05
Modbus RTU Modbus TCP/IP 06
Lonworks FT-10 EZ7 Ethernet 07
Lonworks FT-10 Modbus TCP/IP 08
EZ7 w/Modem EZ7 Ethernet 09
EZ7 w/Modem Modbus TCP/IP 10
EZ7 w/Modem BACnet IP 11

 

Options

Three-phase meter kits are supplied with (3) split-core current sensors.

To order a single-phase, 3-wire meter kit add "-SP" before "KIT" in the model number. (Example: E34-208100-R01-SPKIT)

Single-phase meters will be supplied with (2) split-core current sensors.

 

 


Class 3400 Smart Meter w/ Dual Protocol Communications

Electric Submeter Features

      • •Advanced 4-line display showing:
        0000- kWh
        0000- kWh/Demand (with peak date and time)
        • 0000- Power factor per Phase
          • 0000- Real-time load in kW
          • 0000- Amps per Phase
          • 0000- Volts per Phase

      • • On-board set-up option for:
      • 0000- IP Address
        • 0000- Meter date/time
        • 0000- Load Control Settings
        • 0000- ID codes for EZ7, Modbus and BACnet

      • • Optional expanded feature package provides additional features:
      • 0000- Load control option for load control/shedding
        • 0000- Two external meter inputs (water, gas, BTU, etc.) (stored in channels 5 & 6)
        • 0000- Two pulse outputs (one kWh and one kVARh

        • • 0-2 volt output split-core current sensors allow for enhanced safety and accurate remote mounting of sensors up to 500 feet from meter without power interruption. (Optional solid-core current sensors available in 100 & 200 amp.)

          • Onboard diagnostics and verification system.

          • Built-in RS-485 communications capability supports up to 52 Class 3200, 3400, 5000 meters and/or IDR interval recorders(or combinations not to exceed 52 devices per channel). 00
          Cabling can be either daisy-chain or star configuration, 3-conductor, 18-22 AWG, up to 4,000 feet cable total per channel.

            • Built-in communications
            0000- RS-4850000
            0000- Ethernet
            0000- Ethernet

          • Protocols
          0000- EZ7
          0000- Modbus RTU
          0000- Modbus TCP/IP
          0000- BACnet MS/TP*
          0000- BACnet IP*
          0000- LonWorks FT-10 (Twisted Pair)*

          • Records kWh and kVARh delivered, kWh and kVARh received in first 4 channels. Data stored in 15-minute intervals for up to 72 days or 5-minute intervals for up to 24 days. Maintains interval data storage in a first-in, first-out format.

          • Compatible with E-Mon Energy software via EZ7 protocol for automatic meter reading, billing and profiling of interval energy data.

          • Meter is designed for use on both 3-phase, 3-wire (delta) and 3-phase, 4-wire (wye) circuits. Optional single-phase, 3-wire configuration available.

          • Outdoor NEMA 4X polycarbonate enclosure (standard) with padlocking hasp & mounting flanges for indoor/outdoor installation (stand alone) with one 1 1/16" KO on bottom of enclosure.

          • Optional Enclosure: Industrial grade JIC steel enclosure with padlocking hasp and mounting flanges for indoor installation (stand alone). Knockouts: 1 1/16" (3/4" cond.) on bottom and 7/8" (1/2" cond.) on top of enclosure.

          • UL/CUL Listed. Certified by independent test lab to ANSI C12.20 national accuracy standards. (+/- 0.2% from 1% to 100% of rated load.)

          • Meter meets or exceeds MID accuracy standards.

          • BACnet protocol is BTL certified. LonWorks protocol is LonMark certified.

          • MV-90 Compatible (EZ7 only).


        Click here to view Engineering Specifications for Class 3400 Meters


Downloads/Related Documents

Download E-Mon D-Mon Catalog

Class 3400 Specification Sheet
Class 3400 Installation Overview
Class 3400 Engineering Specifications

Class 3400 Installation Manual
Parallel Current Sensor Rules (Multiple Load Monitoring)
Parallel Current Sensor Diagram (Multiple Load Monitoring)

Communication Protocol Data Points (BACnet, ModBus, LonWorks, etc.)


Complimentary Products

E-Mon Energy Software
Web-Mon