Model Information

class 5000 meter

120/208-240V, 3 Phase
(Supplied with (3) Split-Core Current Sensors)

E50-208100-R*KIT (100 Amp)
E50-208200-R*KIT (200 Amp)

E50-208400-R*KIT (400 Amp)
E50-208800-R*KIT (800 Amp)
E50-2081600R*KIT (1600 Amp)
E50-2083200R*KIT (3200 Amp)



220/380V, 230/400V, 240/415V, 3 Phase
(Supplied with (3) Split-Core Current Sensors)

E50-400100-R*KIT (100 Amp)
E50-400200-R*KIT (200 Amp)

E50-400400-R*KIT (400 Amp)
E50-400800-R*KIT (800 Amp)
E50-4001600R*KIT (1600 Amp)
E50-4003200R*KIT (3200 Amp)



277/480V, 3 Phase
(Supplied with (3) Split-Core Current Sensors)

E50-480100-R*KIT (100 Amp)
E50-480200-R*KIT (200 Amp)

E50-480400-R*KIT (400 Amp)
E50-480800-R*KIT (800 Amp)
E50-4801600R*KIT (1600 Amp)
E50-4803200R*KIT (3200 Amp)




347/600V, 3 Phase, 4 W (Wye Config.)
(Supplied with (3) Split-Core Current Sensors)

E50-600100-R*KIT (100 Amp)
E50-600200-R*KIT (200 Amp)

E50-600400-R*KIT (400 Amp)
E50-600800-R*KIT (800 Amp)
E50-6001600R*KIT (1600 Amp)
E50-6003200R*KIT (3200 Amp)



Enclosure Options

Meters supplied standard in NEMA 4X outdoor enclosures. To order a different enclosure replace "R" in model number with optional enclosure specification.

JIC Steel Enclosure-Specify J
(Example: E50-208100-J01KIT)



Communication Protocol Options

Specify protocol package when ordering all meters. Replace * in model number with protocol package specification below. (Example: E50-4801600R08KIT)

RS-485 Ethernet Specify
EZ7 EZ7 Ethernet 01
Modbus RTU EZ7 Ethernet 02
BACnet MS/TP EZ7 Ethernet 03
EZ7 Modbus TCP/IP 04
EZ7 BACnet IP 05
Modbus RTU Modbus TCP/IP 06
Lonworks FT-10 EZ7 Ethernet 07
Lonworks FT-10 Modbus TCP/IP 08
EZ7 w/Modem EZ7 Ethernet 09
EZ7 w/Modem Modbus TCP/IP 10
EZ7 w/Modem BACnet IP 11

 

Options

Three-phase meter kits are supplied with (3) split-core current sensors.

To order a single-phase, 3-wire meter kit add "-SP" before "KIT" in the model number. (Example: E50-208100-R01-SPKIT)

Single-phase meters will be supplied with (2) split-core current sensors.

 

 


Class 5000 Smart Meter w/ Dual Protocol Communications

Electric Submeter Features

      • •Advanced 4-line display showing:
        0000- kWh
        0000- kWh/Demand (with peak date and time)
        • 0000- Power factor per Phase
          • 0000- Real-time load in kW
          • 0000- Amps per Phase
          • 0000- Volts per Phase

      • • On-board set-up option for:
      • 0000- IP Address
        • 0000- Meter date/time
        • 0000- ID codes for EZ7, Modbus and BACnet

        • • 0-2 volt output split-core current sensors allow for enhanced safety and accurate remote mounting of sensors up to 500 feet from meter without power interruption. (Optional solid-core current sensors available in 100 & 200 amp.)

          • Onboard diagnostics and verification system.

          • Two pulse outputs & two external meter inputs (water, gas, BTU, etc.) (Channels 5 & 6 available via E-Mon Energy only)

          • Phase loss alarm. (N.O. Contact)

          • Built-in RS-485 communications capability supports up to 52 Class 3200, 3400, 5000 meters and/or IDR interval recorders(or combinations not to exceed 52 devices per channel). 00
          Cabling can be either daisy-chain or star configuration, 3-conductor, 18-22 AWG, up to 4,000 feet cable total per channel.

          • Built-In RS-485 & Ethernet Communications. Optional telephone modem available.

          • Protocols
          0000- EZ7
          0000- Modbus RTU
          0000- Modbus TCP/IP
          0000- BACnet MS/TP*
          0000- BACnet IP*
          0000- LonWorks FT-10 (Twisted Pair)*

          • Records kWh and kVARh delivered, kWh and kVARh received in first 4 channels. Data stored in 15-minute intervals for up to 72 days or 5-minute intervals for up to 24 days. Maintains interval data storage in a first-in, first-out format.

          • Compatible with E-Mon Energy software via EZ7 protocol for automatic meter reading, billing and profiling of interval energy data.

          • Meter is designed for use on both 3-phase, 3-wire (delta) and 3-phase, 4-wire (wye) circuits.

          • Outdoor NEMA 4X polycarbonate enclosure (standard) with padlocking hasp & mounting flanges for indoor/outdoor installation (stand alone) with one 1 1/16" KO on bottom of enclosure.

          • Optional Enclosure: Industrial grade JIC steel enclosure with padlocking hasp and mounting flanges for indoor installation (stand alone). Knockouts: 1 1/16" (3/4" cond.) on bottom and 7/8" (1/2" cond.) on top of enclosure.

          • UL/CUL Listed. Certified by independent test lab to ANSI C12.20 national accuracy standards. (+/- 0.2% from 1% to 100% of rated load.)

          • Compatible with both 50 Hz and 60 Hz applications.

          • CE Mark Approved.

          • Meter meets or exceeds MID accuracy standards.

          • BACnet protocol is BTL certified. LonWorks protocol is LonMark certified.

          • MV-90 Compatible (EZ7 only).

          ** Interval data not available via BACnet or LonWorks.

        Click here to view Engineering Specifications for Class 5000 Meters


Downloads/Related Documents

Download E-Mon D-Mon Catalog

Class 5000 Specification Sheet
Class 5000 Installation Overview
Class 5000 Engineering Specifications

Class 5000 Installation Manual
Parallel Current Sensor Rules (Multiple Load Monitoring)
Parallel Current Sensor Diagram (Multiple Load Monitoring)

Communication Protocol Data Points (BACnet, ModBus, LonWorks, etc.)


Complimentary Products

E-Mon Energy Software
Web-Mon

jordan 3 sport blue cheap air jordans louis vuitton outlet jordan 3 sport blue wolf grey 3s michael kors outlet michael kors outlet louis vuitton outlet kate spade outlet jordan 3 wolf grey jordan 3 Wolf Grey wolf grey 3s nike kd vii new jordans cheap jordans louis vuitton outlet louis vuitton outlet online kate spade outlet cheap jordans Sport blue 14s