Model Information
120/208-240V, 3 Phase
(Supplied with (3) Split-Core Current Sensors)
E50-208100-R*KIT (100 Amp)
E50-208200-R*KIT (200 Amp)
E50-208400-R*KIT (400 Amp)
E50-208800-R*KIT (800 Amp)
E50-2081600R*KIT (1600 Amp)
E50-2083200R*KIT (3200 Amp)
277/480V, 3 Phase
(Supplied with (3) Split-Core Current Sensors)
E50-480100-R*KIT (100 Amp)
E50-480200-R*KIT (200 Amp)
E50-480400-R*KIT (400 Amp)
E50-480800-R*KIT (800 Amp)
E50-4801600R*KIT (1600 Amp)
E50-4803200R*KIT (3200 Amp)
347/600V, 3 Phase
(Supplied with (3) Split-Core Current Sensors)
E50-600100-R*KIT (100 Amp)
E50-600200-R*KIT (200 Amp)
E50-600400-R*KIT (400 Amp)
E50-600800-R*KIT (800 Amp)
E50-6001600R*KIT (1600 Amp)
E50-6003200R*KIT (3200 Amp)
Enclosure
Options
Meters supplied standard in NEMA 4X outdoor enclosures. To order a different enclosure replace "R" in model number with optional enclosure specification.
JIC Steel Enclosure-Specify J
(Example: E50-208100-J01KIT)
Communication Protocol Options
Specify protocol package when ordering all meters. Replace * in model number with protocol package specification below. (Example: E50-4801600R08KIT)
| RS-485 | Ethernet | Specify |
|---|---|---|
| EZ7 | EZ7 Ethernet | 01 |
| Modbus RTU | EZ7 Ethernet | 02 |
| BACnet MS/TP | EZ7 Ethernet | 03 |
| EZ7 | Modbus TCP/IP | 04 |
| EZ7 | BACnet IP | 05 |
| Modbus RTU | Modbus TCP/IP | 06 |
| Lonworks FT-10 | EZ7 Ethernet | 07 |
| Lonworks FT-10 | Modbus TCP/IP | 08 |
| EZ7 w/Modem | EZ7 Ethernet | 09 |
| EZ7 w/Modem | Modbus TCP/IP | 10 |
| EZ7 w/Modem | BACnet IP | 11 |
Class 5000 Smart Meter w/ Dual Protocol Communications
Electric Submeter Features
- •Advanced 4-line display showing:
0000- kWh
0000- kWh/Demand (with peak date and time)
- 0000- Power factor per Phase
- 0000- Real-time load in kW
- 0000- Amps per Phase
- 0000- Volts per Phase
- • On-board set-up option for:
- 0000- IP Address
- 0000- Meter date/time
- 0000- ID codes for EZ7, Modbus and BACnet
Click here to view Engineering Specifications for Class 5000 Meters
• 0-2 volt output split-core current sensors allow for enhanced safety and accurate remote mounting of sensors up to 500 feet from meter without power interruption. (Optional solid-core current sensors available in 100 & 200 amp.)
• Onboard diagnostics and verification system.
• Two pulse outputs & two external meter inputs (water, gas, BTU, etc.) (Channels 5 & 6 available via E-Mon Energy only)
• Phase loss alarm. (N.O. Contact)
• Built-in RS-485 communications capability supports up to 52 Class 3200, 3400, 5000 meters and/or IDR interval recorders(or combinations not to exceed 52 devices per channel). 00
Cabling can be either daisy-chain or star configuration, 3-conductor, 18-22 AWG, up to 4,000 feet cable total per channel.• Built-In RS-485 & Ethernet Communications. Optional telephone modem available.
• Protocols
0000- EZ7
0000- Modbus RTU
0000- Modbus TCP/IP
0000- BACnet MS/TP*
0000- BACnet IP*
0000- LonWorks FT-10 (Twisted Pair)*• Records kWh and kVARh delivered, kWh and kVARh received in first 4 channels. Data stored in 15-minute intervals for up to 72 days or 5-minute intervals for up to 24 days. Maintains interval data storage in a first-in, first-out format.
• Compatible with E-Mon Energy software via EZ7 protocol for automatic meter reading, billing and profiling of interval energy data.
• Meter is designed for use on both 3-phase, 3-wire (delta) and 3-phase, 4-wire (wye) circuits.
• Outdoor NEMA 4X polycarbonate enclosure (standard) with padlocking hasp & mounting flanges for indoor/outdoor installation (stand alone) with one 1 1/16" KO on bottom of enclosure.
• Optional Enclosure: Industrial grade JIC steel enclosure with padlocking hasp and mounting flanges for indoor installation (stand alone). Knockouts: 1 1/16" (3/4" cond.) on bottom and 7/8" (1/2" cond.) on top of enclosure.
• UL/CUL Listed. Certified by independent test lab to ANSI C12.20 national accuracy standards. (+/- 0.2% from 1% to 100% of rated load.)
• MV-90 Compatible (EZ7 only).
Downloads/Related Documents
• Class 5000 Specification Sheet
• Class 5000 Installation Overview
• Class 5000 Engineering Specifications
• Class 5000 Installation Manual
• Parallel Current Sensor Rules (Multiple Load Monitoring)
• Parallel Current Sensor Diagram (Multiple Load Monitoring)
• Communication Protocol Data Points (BACnet, ModBus, LonWorks, etc.)
Complimentary Products