Model Information

IDR Interval Data RecorderIDR Interval Data Recorders

Component Models:

IDR-8 (Up to 8 meters)
IDR-16 (Up to 16 meters)

*For optional screw terminals in place of all RJ jacks add suffix ST to the model. Example: IDR-8-ST

* For IDR-16 with 8 RJ jacks and 8 screw terminals add suffix RJST to the end of the model. Example: IDR-16-RJST

Built-In Communication Options

Telephone Modem (Suffix M)
Ethernet Communication (Suffix E)
Modbus RTU (Suffix RTU)
*Modbus TCP/IP (Suffix ERTU)
*BACnet IP (Suffix EB)
BACnet MS/TP (Suffix B)
Lonworks TP (Suffix LTP)

* Modbus TCP/IP and BACnet IP communicate over Ethernet. No RS-485 daisy-chain capabilities with Modbus TCP/IP & BACnet IP. Each IDR must connect directly to the BACnet/Modbus backbone and have a unique IP address.



 

E-Mon IDR Interval Data Recorders

Overview

E-Mon IDR Interval Data Recorders collect and store interval energy data from meters in time-stamped intervals for later download. Whereas a meter, such as an E-Mon D-Mon submeter, continuously reads energy usage as it occurs, an IDR collects and stores meter information at specified time periods, allowing for profiling of meter data and more detailed comparative analysis or billing.

The IDR collects kWh an kW demand information from meters in 5, 15, 30 or 60-minute interval periods. Data can be collected from up to 8 or 16 separate meters/channels of information. Up to 36 days of 15-minute interval data is stored in onboard memory. The IDR interval meter data can be accessed via a variety of communication options including; telephone, Ethernet, ModBus, BACnet, Internet, LonWorks TP or MV-90. Data can be used to interface with E-Mon Energy Automatic Meter Reading & Billing software, Building Automation/Management Systems or other energy software.

Features

• Reads & records up to 8 or 16 E-Mon D-Mon electric meters.

• IDR-ST model can accept contact closure type pulse inputs from other types of meters (water, gas, BTU, steam, etc.)

• RS-485 communications capability supports the following connection configurations (or combinations not to exceed 52 devices per channel):

- Up to 52 IDR-8 interval data recorders
- Up to 26 IDR-16 interval data recorders (IDR-16 counts as two devices)

Cabling can be either daisy-chain or star configuration, 4-conductor, 24-26 AWG, up to 4,000 cable feet total per channel.

• Communications Options:

- RS-232/485 (Standard)
- Telephone Modem
- Ethernet
- Modbus RTU or Modbus TCP/IP
- BACnet IP or BACnet MS/TP
- LonWorks TP (Twisted Pair)

• Internal data storage-36 days of 15-minute intervals. Maintains last 36 days of data.

• Reads kWh (kilowatt-hours) and reads kW (demand) in 15, 30 or 60-minute kW periods.

• Standard IDRs do not require a separate power source (power supplied by E-Mon D-Mon electric meters.) IDR-ST models require a separate 120V power source (included with IDR-ST models.)

• Maintains data in case of power outage.

• Industrial-grade JIC steel enclosure with padlocking hasp and mounting flanges. (For indoor use only.)

• Three 1 1/16" knockouts (3/4" conduit) on bottom of enclosure.

• IDR data accumulators can be mounted on the inside back wall of the MMU cabinet and shipped from the factory in one complete package.

• MV-90 compatible.

Downloads/Related Documents

Download E-Mon D-Mon Catalog

IDR Specifications
• IDR Installation Instructions
BACnet Object Descriptors
Modbus Point Map
E-Mon Energy Software Specifications
E-Mon Energy System Configuration
E-Mon Energy Engineering Specifications
E-Mon Energy System Options


Complimentary Products

All E-Mon D-Mon Stand Alone & MMU Style Meters (See Metering Products Section)
E-Mon Energy System Options