Model Information

Class 1000 submeter

All E-Mon meters kits include split-core current sensors.

e-mon split core current sensor size dimension chart

E-Mon Split-Core Current Sensor Set Model Numbers
(Sets are shipped in complete sets of three (3) pieces.)

CS25 (25 Amp)
CS50 (50 Amp)
CS100 (100 Amp)
CS200 (200 Amp)
CS400 (400 Amp)
CS800 (800 Amp)
CS1600 (1600 Amp)
CS3200 (3200 Amp)

NOTE: E-Mon current sensors are for use with E-Mon D-Mon meters only

 

To order 100 or 200 Amp solid-core current sensors, specify SOLID CORE when ordering meter or extra sensors.

 

 

 

E-Mon D-Mon Split-Core Current Sensors

 

Features

• E-Mon's patented 0-2V output split-core current sensors allow users to easily monitor energy usage in new or retrofit applications. Sensors are sized according to the meter they are installed with and are sized to fit the typical wire size for that amperage.

• E-Mon current sensors are installed inside the electrical panel and "snap" around the load wires to be monitored. The sensors can monitor anything from a single branch circuit, to multiple circuits, to the entire building.

• E-Mon current sensors can be installed up to 2,000 feet away from the meter (500 feet on Class 3x00 & Class 5000 meters) by extending the current sensor leads using #14-22 AWG wire (stranded/twisted not required). 3' leads are supplied from the factory, consult local electrical costs for proper wiring size requirements.

• Current sensors can be installed around multiple load wires from the same source to provide a cumulative reading of usage for all of the loads. Note: Phase correspondence is required, and all loads must be from the same voltage source/transformer.

• Multiple sets of current sensors can be installed on one meter to provide a cumulative reading of multiple loads from different panels. Up to 3 sets of sensors can be installed on one meter. Note: Phase correspondence is required, all loads must be from the same voltage source/transformer, and all current sensors must be of the same amperage rating..

• Current sensors can be used for subtractive metering. An example of subtractive metering is one set of current sensors installed around the main load wires in a panel. A second set of current sensors is installed around the load wires going to a subpanel, but the current sensors are reversed during installation. This will provide a net reading of the total panel less the sub panel. Note: Phase correspondence is required, all loads must be from the same voltage source/transformer, and all current sensors must be of the same amperage rating.

• Optional solid-core current sensors are available in 100 & 200 amp configuration, specify when ordering.

 

Split-Core Current Sensor Dimensions

 

25-200 amp sensor picture 400 amp split core current sensor
800-1600 amp split core sensor 3200 amp split core sensor

 


Downloads/Related Documents

Download E-Mon D-Mon Catalog

Split-Core Current Sensor Specifications
Split-Core Current Sensor Assembly